GSO IEC 61472-2:2024
IEC 61472-2:2021
Gulf Standard
Current Edition
·
Approved on
14 October 2024
Live working - Minimum approach distances - Part 2: Method of determination of the electrical component distance for AC systems from 1,0 kV to 72,5 kV
GSO IEC 61472-2:2024 Files
English
32 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable.
You can acquire it directly from its source or from one of the member countries stores
GSO IEC 61472-2:2024 Scope
IEC 61472-2:2021 specifies a method for determining the electrical component of the minimum approach distances for live working, for AC systems 1 kV up to and including 72,5 kV. This document addresses system overvoltages and the working air distances between equipment and/or workers at different potentials.
The withstand voltage and minimum approach distances determined by the method described in this document can be used only if the following working conditions prevail:
workers are trained for, and skilled in, working live lines or close to live conductors or equipment;
the operating conditions are adjusted so that the statistical overvoltage does not exceed the value selected for the determination of the required withstand voltage;
transient overvoltages are the determining overvoltages;
tool insulation has no continuous film of moisture present on the surface;
no lightning is observed within 10 km of the work site;
allowance is made for the effect of the conducting components of tools.
The withstand voltage and minimum approach distances determined by the method described in this document can be used only if the following working conditions prevail:
workers are trained for, and skilled in, working live lines or close to live conductors or equipment;
the operating conditions are adjusted so that the statistical overvoltage does not exceed the value selected for the determination of the required withstand voltage;
transient overvoltages are the determining overvoltages;
tool insulation has no continuous film of moisture present on the surface;
no lightning is observed within 10 km of the work site;
allowance is made for the effect of the conducting components of tools.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
GSO 2693:2022
Gulf Standard
The GCC Terrestrial Radio Receiver Specifications for AM/FM/T-DAB+
Recently Published from Electrical Sector
GSO IEC 60335-2-26:2025
IEC 60335-2-26:2024
Gulf Standard
Household and similar electrical appliances - Safety - Part 2-26: Particular requirements for clocks
GSO IEC TS 62271-314:2025
IEC TS 62271-314:2024
Gulf Standard
High-voltage switchgear and controlgear - Part 314: Direct current disconnectors and earthing switches
GSO IEC 61058-2-1:2025
IEC 61058-2-1:2018
Gulf Standard
Switches for appliances - Part 2-1: Particular requirements for cord switches
GSO IEC 60034-2-3:2025
IEC 60034-2-3:2024
Gulf Standard
Rotating electrical machines - Part 2-3: Specific test methods for determining losses and efficiency of converter-fed AC motors