GSO ISO 16637:2017

ISO 16637:2016
Gulf Standard   Current Edition · Approved on 03 October 2017

Radiological protection -- Monitoring and internal dosimetry for staff members exposed to medical radionuclides as unsealed sources

GSO ISO 16637:2017 Files

English 28 Pages
Current Edition Reference Language

GSO ISO 16637:2017 Scope

This International Standard specifies the minimum requirements for the design of professional programmes to monitor workers exposed to the risk of internal contamination via inhalation by the use of radionuclides as unsealed sources in nuclear medicine imaging and therapy departments. It establishes principles for the development of compatible goals and requirements for monitoring programmes and, when adequate, dose assessment. It presents procedures and assumptions for the risk analysis, for the monitoring programmes, and for the standardized interpretation of monitoring data. This International Standard addresses the following items: a) purposes of monitoring and monitoring programmes; b) description of the different categories of monitoring programmes; c) quantitative criteria for conducting monitoring programmes; d) suitable methods for monitoring and criteria for their selection; e) information that has to be collected for the design of a monitoring programme; f) general requirements for monitoring programmes (e.g. detection limits, tolerated uncertainties); g) frequencies of measurements; h) procedures for dose assessment based on reference levels for routine and special monitoring programmes; i) assumptions for the selection of dose-critical parameter values; j) criteria for determining the significance of individual monitoring results; k) interpretation of workplace monitoring results; l) uncertainties arising from dose assessments and interpretation of bioassays data; m) reporting/documentation; n) quality assurance. This International Standard does not address the following: — monitoring and internal dosimetry for the workers exposed to laboratory use of radionuclides such as radioimmunoassay techniques; — monitoring and internal dosimetry for the workers involved in the operation, maintenance, and servicing of PET cyclotrons; — detailed descriptions of measuring methods and techniques; — dosimetry for litigation cases; — modelling for the improvement of internal dosimetry; — the potential influence of medical treatment of the internal contamination; — the investigation of the causes or implications of an exposure; — dosimetry for ingestion exposures and for contaminated wounds.

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners
GSO 2063:2023
 
Gulf Standard
Cosmetic Products - Hair Conditioner (Balsam)
GSO 1223:2023
 
Gulf Standard
Cosmetic Products-Deodorants

Recently Published from Health Sector

GSO ISO 12219-9:2025
ISO 12219-9:2019 
Gulf Standard
Interior air of road vehicles — Part 9: Determination of the emissions of volatile organic compounds from vehicle interior parts — Large bag method
GSO ASTM E3032:2025
ASTM E3032:22 
Gulf Standard
Standard Guide for Climate Resiliency Planning and Strategy
GSO ASTM E3356:2025
ASTM E3356:22 
Gulf Standard
Standard Guide for Stakeholder Engagement on Environmental Risk Management and Climate
GSO ISO 12219-1:2025
ISO 12219-1:2021 
Gulf Standard
Interior air of road vehicles — Part 1: Whole vehicle test chamber — Specification and method for the determination of volatile organic compounds in cabin interiors