GSO ISO 10993-13:2016

ISO 10993-13:2010
Gulf Standard   Current Edition · Approved on 22 December 2016

Biological evaluation of medical devices -- Part 13: Identification and quantification of degradation products from polymeric medical devices

GSO ISO 10993-13:2016 Files

English 14 Pages
Current Edition Reference Language

GSO ISO 10993-13:2016 Scope

This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use. This part of ISO 10993 describes two test methods to generate degradation products, an accelerated degradation test as a screening method and a real-time degradation test in a simulated environment. For materials that are intended to polymerize in situ, the set or cured polymer is used for testing. The data generated are used in the biological evaluation of the polymer. This part of ISO 10993 considers only non-resorbable polymers. Similar but appropriately modified procedures may be applicable for resorbable polymers. This part of ISO 10993 considers only those degradation products generated by a chemical alteration of the finished polymeric device. It is not applicable to degradation of the device induced during its intended use by mechanical stress, wear or electromagnetic radiation or biological factors such as enzymes, other proteins and cellular activity. NOTE An informative text discussing environmental stress cracking (ESC) of polymers is included as a potential aid to the design of degradation studies (see Annex B). The biological activity of the debris and soluble degradation products is not addressed in this part of ISO 10993, but should be evaluated according to the principles of ISO 10993-1, ISO 10993-16 and ISO 10993-17. Because of the wide range of polymeric materials used in medical devices, no specific analytical techniques are identified or given preference. No specific requirements for acceptable levels of degradation products are provided in this part of ISO 10993.

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners
GSO 1223:2023
 
Gulf Standard
Cosmetic Products-Deodorants
GSO 2156:2023
 
Gulf Standard
Cosmetic Products – Natural Henna

Recently Published from Health Sector

GSO ASTM F404:2026
ASTM F404:21 
Gulf Standard
Standard Consumer Safety Specification for High Chairs
GSO ISO 19223-2:2026
ISO 19223-2:2025 
Gulf Standard
Lung ventilators and related equipment — Vocabulary and semantics — Part 2: High frequency and jet ventilation
GSO ASTM F619:2026
ASTM F619:20(2025) 
Gulf Standard
Standard Practice for Extraction of Materials Used in Medical Devices
GSO ISO 16687:2026
ISO 16687:2025 
Gulf Standard
Impact assessment for museums