GSO ISO 16017-1:2016
ISO 16017-1:2000
Gulf Standard
Current Edition
·
Approved on
22 December 2016
Indoor, ambient and workplace air -- Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography -- Part 1: Pumped sampling
GSO ISO 16017-1:2016 Files
English
32 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable.
You can acquire it directly from its source or from one of the member countries stores
GSO ISO 16017-1:2016 Scope
This part of ISO 16017 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to ambient, indoor and workplace atmospheres and the assessment of emissions from materials in small- or full-scale test chambers.
This part of ISO 16017 is appropriate for a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of sorbents 1) are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds will generally require derivatization, very low boiling compounds will only be partially retained by the sorbents, depending on ambient temperature, and can only be estimated qualitatively. Semi-volatile compounds will be fully retained by the sorbents, but may only be partially recovered. Compounds for which this part of ISO 16017 has been tested are given in tables. This part of ISO 16017 may be applicable to compounds not listed, but in these cases it is advisable to use a back-up tube containing the same or a stronger sorbent.
This part of ISO 16017 is applicable to the measurement of airborne vapours of VOCs in a concentration range of approximately 0,5 mg/ m3 to 100 mg/m3 individual compound.
The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample-splitting capability of the analytical instrumentation used. The sorptive capacity is measured as a breakthrough volume of air, which determines the maximum air volume that shall not be exceeded when sampling.
The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents such as Carbopack/Carbotrap type materials, carbonized molecular sieves and molecular sieves such as Spherocarb, or pure charcoal; at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers such as Chromosorbs and Porapaks. Sensitivity is typically limited to 0,5 μg/m3 for 10-litre air samples with this latter group of sorbents because of their inherent high background.
The procedure specified in this part of ISO 16017 is applicable to low flowrate personal sampling pumps and gives a time-weighted average result. It is not applicable to the measurement of instantaneous or short-term fluctuations in concentration.
Best Sellers From Chemical and Textile Sector
GSO 1943:2024
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 151:2022
Gulf Standard
Synthetic Detergents –Household Synthetic Detergents Powder
GSO 2528:2024
Gulf Technical Regulation
Cosmetic products – Technical Regulation of Cosmetic and Personal Care Products Claims
GSO 2555:2021
Gulf Technical Regulation
General Safety Requirements of Household Detergents
Recently Published from Chemical and Textile Sector
GSO ISO 15384:2025
ISO 15384:2018
Gulf Standard
Protective clothing for firefighters — Laboratory test methods and performance requirements for wildland firefighting clothing
GSO EN 361:2025
EN 361:2002
Gulf Standard
Personal protective equipment against falls from a height - Full body harnesses
GSO ASTM D4009:2025
ASTM D4009:92(2023)
Gulf Standard
Standard Guide for Foam Stability of Hand Dishwashing Detergents
GSO ASTM D2257:2025
ASTM D2257:20
Gulf Standard
Standard Test Method for Extractable Matter in Textiles