GSO IEC 60034-18-31:2015

IEC 60034-18-31:2012
Gulf Standard   Current Edition · Approved on 03 September 2015

Rotating electrical machines - Part 18-31: Functional evaluation of insulation systems - Test procedures for form-wound windings - Thermal evaluation and classification of insulation systems used in rotating machines

GSO IEC 60034-18-31:2015 Files

English 54 Pages
Current Edition Reference Language

GSO IEC 60034-18-31:2015 Scope

This part of IEC 60034 describes thermal endurance test procedures for classification of insulation systems used in a.c. or d.c. rotating electrical machines with indirect cooling and form-wound windings. The test performance of a candidate insulation system is compared to the test performance of a reference insulation system with proven service experience. The test procedures described in IEC 60034-18-31 are intended to compare the thermal endurance performance of the mainwall insulation between conductor(s) and ground and,where required by the design of the coil or bar, the insulation between the turns. The test is not intended to simulate the in-service mechanical stresses experienced by the endwinding bracing or support materials. It does not include the evaluation of thermomechanical deterioration by expansion and contraction of insulation during temperature cycling. IEC 60034-18-1 describes general testing principles applicable to thermal endurance testing of insulation systems used in rotating electrical machines. The principles of IEC 60034-18-1 are followed unless otherwise stated in IEC60034-18-31. The thermal class for the insulation system refers to its maximum allowed (“hot spot”) temperature. The average temperature measured in service should not exceed the allowed temperature rise according to IEC 60034-1. NOTE 1 Large machines, especially synchronous generators using bars, may require special thermal evaluation test procedures which are not included in this part. NOTE 2 Recommended parameters for the diagnostic test may be applied according to IEC 60034-18-42 to formwound coils designed with Type II insulation systems for use in converter applications.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines
GSO 2693:2022
 
Gulf Standard
The GCC Terrestrial Radio Receiver Specifications for AM/FM/T-DAB+

Recently Published from Electrical Sector

GSO IEC TR 63396:2025
IEC TR 63396:2021 
Gulf Standard
Noise measurement method on power capacitors
GSO IEC TS 61850-7-7:2025
IEC TS 61850-7-7:2018 
Gulf Standard
Communication networks and systems for power utility automation - Part 7-7: Machine-processable format of IEC 61850-related data models for tools
GSO IEC 62271-101:2025
IEC 62271-101:2021 
Gulf Standard
High-voltage switchgear and controlgear - Part 101: Synthetic testing
GSO IEC 60287-2-1:2025
IEC 60287-2-1:2023 
Gulf Standard
Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance