GSO IEC 60317-33:2014

IEC 60317-33:1990
Gulf Standard   Current Edition · Approved on 25 December 2014

Amendment 2 - Specifications for particular types of winding wires - Part 33: Glass-fibre wound resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 200

GSO IEC 60317-33:2014 Files

English 15 Pages
Current Edition Reference Language

GSO IEC 60317-33:2014 Scope

This International Standard specifies requirements of glass-fibre wound impregnated, bare grade 1 or grade 2 enamelled rectangular copper winding wire, temperature index 200. The impregnating agent can be, for instance, polyesterimide or silicon resin based. NOTE - For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified. The enamelled wire shall be based on one of the following standards and shall be agreed between purchaser and supplier. IEC 60317-28:1990, Specifications for particular types of winding wires – Part 28: Polyesterimide enamelled rectangular copper wire, class 180 IEC 60317-29:1990, Specifications for particular types of winding wires – Part 29: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular copper wire, class 200 IEC 60317-30:1990, Specifications for particular types of winding wires – Part 30: Polyimide enamelled rectangular copper wire, class 220 When an enamelled wire is used, it must have a minimum class of 180. The temperature index of the glass-fibre wound impregnated wire is dependent upon the type of impregnating agent used. The impregnating agent applied to the glass fibre should have a minimum temperature index of 200. The glass-fibre covering may be: a) a single layer of glass-fibre; b) double layer of glass-fibre, with one layer applied in the direction opposite to that of the other layer. The range of nominal conductor dimensions covered by this standard is: – width: min. 2,0 mm max. 16,0 mm; – thickness: min. 0,80 mm max. 5,60 mm. The specified combinations of width and thickness as well as the specified width/thickness ratio are given in IEC 60317-0-4.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines
GSO 1899:2016
 
Gulf Standard
GCC Standard voltages and frequencies for AC transmission and distribution systems

Recently Published from Electrical Sector

GSO ISO 20816-21:2026
ISO 20816-21:2025 
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019 
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC TR 63411:2026
IEC TR 63411:2025 
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO IEC 61362:2026
IEC 61362:2024 
Gulf Standard
Guidelines to specification of hydraulic turbine governing systems