GSO IEC/TS 61000-3-4:2014

IEC TS 61000-3-4:1998
Gulf Standard   Current Edition · Approved on 25 December 2014

Electromagnetic compatibility (EMC) - Part 3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A

GSO IEC/TS 61000-3-4:2014 Files

English 29 Pages
Current Edition Reference Language

GSO IEC/TS 61000-3-4:2014 Scope

This part of IEC 61000 deals with the emission of disturbances due to harmonics. The recommendations of this technical report are applicable to electrical and electronic equipment with a rated input current exceeding 16 A per phase and intended to be connected to public low-voltage a.c. distribution systems of the following types: – nominal voltage up to 240 V, single-phase, two or three wires; – nominal voltage up to 600 V, three-phase, three or four wires; – nominal frequency 50 Hz or 60 Hz. Other distribution systems are excluded. Tests according to this report are type tests of complete pieces of equipment, for example a speed variable fan, and not of components, for example a converter. Connection of this equipment to the supply generally requires special agreement between the supply authority and the consumer. This consent will depend upon several factors including the expected levels of disturbance caused by the equipment and the actual situation at the connection point to the power supply system. These recommendations specify the information required to enable a supply authority to assess equipment regarding harmonic disturbance and to decide whether or not the equipment is acceptable for connection with regard to the harmonic distortion aspect. NOTE 1 – For these types of equipment only general recommendations on assessment of disturbances can be given. There is no guarantee that the connection of equipment complying with these recommendations will be allowed in all cases, as the consent to connect equipment to the supply depends on the level of disturbance caused by the equipment and the load conditions in the network. NOTE 2 – These recommendations can also be applied to equipment with a lower rated input current but requiring special consent of the supply authority (see IEC 61000-3-2). NOTE 3 – These recommendations are not applicable to active filters. Guidance is given on: a) required short-circuit power for harmonics emitting equipment tested or simulated under specified conditions; b) methods for type tests or simulations.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines
GSO 2693:2022
 
Gulf Standard
The GCC Terrestrial Radio Receiver Specifications for AM/FM/T-DAB+

Recently Published from Electrical Sector

GSO 195:1994
 
Gulf Standard
METHODS OF TEST FOR ADHESIVE INSULATING TAPES FOR ELECTRICAL PURPOSES
GSO 31:1984
 
Gulf Standard
METHODS OF TEST FOR PVC-INSULATED CABLES AND CORDS WITH CIRCULAR COPPER CONDUCTORS
GSO 723:1997
 
Gulf Standard
Methods of test for telephone sets.
GSO 1842:2007
 
Gulf Standard
METHODS OF TESTING FOR PLUGS AND SOCKET OUTLETS FOR VOLTAGES FROM 127V AND UP TO 250V FOR HOUSEHOLD AND SIMILAR GENERAL USE