GSO IEC 61377-3:2014
IEC 61377-3:2002
Gulf Standard
Current Edition
·
Approved on
25 December 2014
Railway applications - Rolling stock - Part 3: Combined testing of alternating current motors, fed by an indirect convertor, and their control system
GSO IEC 61377-3:2014 Files
English
47 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable.
You can acquire it directly from its source or from one of the member countries stores
GSO IEC 61377-3:2014 Scope
This International Standard applies to the combinations of motor(s), indirect convertors and their control system and its object is to specify:
− the performance characteristics of electric drives consisting of a convertor, alternating current motors, and the related control system;
− methods of verifying these performance characteristics by tests.
Two categories of combined systems can be considered:
a) Alternating current motors fed from a convertor without any control between the mechanical output (torque, speed) and the convertor itself (mostly auxiliary motors, for example cooling fan motors). The motor works exactly as if it were fed from a busbar (at variable frequency and voltage or not).
b) Alternating current motor(s) (paralleled or not) with a control between the mechanical output and the inverter.
The first category of systems is tested according to IEC 60349-2 and IEC 61287-1.
This standard applies to the second category, mainly traction drives. IEC 60349-2 applies to convertor-fed alternating current motors, IEC 61287-1 to power electronic convertors; IEC 60571 applies to electronic equipment; this standard applies to the combination of motor(s), convertors, and their control system. As a consequence, IEC 60349-2 describes the tests to demonstrate the compliance of the motor to its specification, IEC 61287-1 does the same for the convertor. It is self-evident that some of the tests mentioned in this standard may in general replace the corresponding ones described in the above mentioned standards. An agreement should be reached between the parties to avoid the duplication of tests.
A complete combined test is heavy, and often requires high power, which is not always available in workshop. An agreement between user and manufacturer may be reached to allow testing either in the workshop or on the vehicle.
At the time of drafting of this standard, only the following combinations of motors and inverters have been used for traction applications, but it may also apply to other combinations which may be used in the future:
− asynchronous motors fed by voltage stiff (voltage source) inverter;
− asynchronous motors fed by current stiff (current source) inverter;
− synchronous motors fed by current stiff (current source) inverter.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
GSO 1899:2016
Gulf Standard
GCC Standard voltages and frequencies for AC transmission and distribution systems
Recently Published from Electrical Sector
GSO CEN/TR 16999:2026
CEN/TR 16999:2019
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC TR 63411:2026
IEC TR 63411:2025
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise