GSO ISO 10313:2014

ISO 10313:1993
Gulf Standard   Current Edition · Approved on 06 August 2014

Ambient air - Determination of the mass concentration of ozone -Chemiluminescence method

GSO ISO 10313:2014 Files

Arabic 16 Pages
Current Edition
English 9 Pages
Current Edition Reference Language

GSO ISO 10313:2014 Scope

1 .l General This International Standard specifies a chemiluminescence method for the determination of the mass concentration of ozone in ambient air. The method is applicable to the determination of the mass concentration of ozone between 2 pg/m3 [O,OOl ppm(V/V)] and 10 mg/m3 [5 ppm(V/V)] at the reference conditions of 25 “C and 101,3 kPa. Ultraviolet (UV) photometry is specified as the primary calibration method because of its proven accuracy and specificity to ozone. The use of transfer Standards is allowed if they have been previously calibrated against the primary calibration method. 1.2 Limitations The chemiluminescent reaction of ozone with ethylene is not subject to interference from any of the common air pollutants. However, particulate matter, if not removed, will accumulate in the sampling line and may Cause a measurable destruction of ozone. If particulate matter is allowed to enter the reaction chamber of the analyser, it will not only scatter the emitted light but will also accumulate on the Optical window, thereby causing further attenuation of the emitted light. Also, any nitrogen(ll) Oxide in the sampled air will to some extent react with the ambient ozone; therefore, the time during which the ambient air remains in the sampling line must be sufficiently short to keep this effect to a minimum. NOTE 1 It has been reported by some researchers that, at about 80 % relative humidity and 22 “C, the responses for some commercially available chemiluminescence analysers were about 10 % higher than that for dry air. However, comparisons of ambient ozone measurements using commercially available chemiluminescence and UV-photometric analysers showed no significant differentes. This suggests that, in practice, any errors associated with calibrations using dry air are compensated by other effects.

Best Sellers From Metrology Sector

GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
GSO OIML R 76-1:2009
OIML R 76-1:2006 
Gulf Standard
Non-automatic weighing instruments – Part 1: Metrological and technical requirements - Tests
GSO OIML R111-1:2007
OIML R111-1:2004 
Gulf Standard
Weights of classes E1, E2,F1,F2,M1,M1-2,M2,M2-3 and M3 Part 1: Metrological and Technical requirements

Recently Published from Metrology Sector

GSO ISO 10713:2026
ISO 10713:2025 
Gulf Standard
Jewellery and precious metals — Gold alloy coatings
GSO ISO 20816-2:2026
ISO 20816-2:2017 
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 2: Land-based gas turbines, steam turbines and generators in excess of 40 MW, with fluid-film bearings and rated speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min and 3 600 r/min
GSO IEC 61452:2026
IEC 61452:2021 
Gulf Standard
Nuclear instrumentation - Measurement of activity or emission rate of gamma-ray emitting radionuclides - Calibration and use of germanium-based spectrometers
GSO ISO 25178-605:2026
ISO 25178-605:2025 
Gulf Standard
Geometrical product specifications (GPS) — Surface texture: Areal — Part 605: Design and characteristics of non-contact (point autofocus probe) instruments