GSO ISO 10313:2014
ISO 10313:1993
Gulf Standard
Current Edition
·
Approved on
06 August 2014
Ambient air - Determination of the mass concentration of ozone -Chemiluminescence method
GSO ISO 10313:2014 Files
Arabic
16 Pages
Current Edition
English
9 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable.
You can acquire it directly from its source or from one of the member countries stores
GSO ISO 10313:2014 Scope
1 .l General
This International Standard specifies a chemiluminescence
method for the determination of the
mass concentration of ozone in ambient air.
The method is applicable to the determination of the
mass concentration of ozone between 2 pg/m3
[O,OOl ppm(V/V)] and 10 mg/m3 [5 ppm(V/V)] at the
reference conditions of 25 “C and 101,3 kPa.
Ultraviolet (UV) photometry is specified as the primary
calibration method because of its proven accuracy and
specificity to ozone. The use of transfer Standards is
allowed if they have been previously calibrated against
the primary calibration method.
1.2 Limitations
The chemiluminescent reaction of ozone with
ethylene is not subject to interference from any of the
common air pollutants. However, particulate matter,
if not removed, will accumulate in the sampling line
and may Cause a measurable destruction of ozone. If
particulate matter is allowed to enter the reaction
chamber of the analyser, it will not only scatter the
emitted light but will also accumulate on the Optical
window, thereby causing further attenuation of the
emitted light. Also, any nitrogen(ll) Oxide in the sampled
air will to some extent react with the ambient
ozone; therefore, the time during which the ambient
air remains in the sampling line must be sufficiently
short to keep this effect to a minimum.
NOTE 1 It has been reported by some researchers that,
at about 80 % relative humidity and 22 “C, the responses for
some commercially available chemiluminescence analysers
were about 10 % higher than that for dry air. However,
comparisons of ambient ozone measurements using commercially
available chemiluminescence and UV-photometric
analysers showed no significant differentes. This suggests
that, in practice, any errors associated with calibrations using
dry air are compensated by other effects.
Best Sellers From Metrology Sector
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages
GSO OIML R 76-1:2009
OIML R 76-1:2006
Gulf Standard
Non-automatic weighing instruments –
Part 1: Metrological and technical requirements - Tests
GSO OIML R111-1:2007
OIML R111-1:2004
Gulf Standard
Weights of classes E1, E2,F1,F2,M1,M1-2,M2,M2-3 and M3
Part 1: Metrological and Technical requirements
Recently Published from Metrology Sector
GSO ISO 10713:2026
ISO 10713:2025
Gulf Standard
Jewellery and precious metals — Gold alloy coatings
GSO ISO 20816-2:2026
ISO 20816-2:2017
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 2: Land-based gas turbines, steam turbines and generators in excess of 40 MW, with fluid-film bearings and rated speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min and 3 600 r/min
GSO IEC 61452:2026
IEC 61452:2021
Gulf Standard
Nuclear instrumentation - Measurement of activity or emission rate of gamma-ray emitting radionuclides - Calibration and use of germanium-based spectrometers
GSO ISO 25178-605:2026
ISO 25178-605:2025
Gulf Standard
Geometrical product specifications (GPS) — Surface texture: Areal — Part 605: Design and characteristics of non-contact (point autofocus probe) instruments