GSO ISO 16934:2009
ISO 16934:2007
Gulf Standard
Current Edition
·
Approved on
11 February 2009
Glass in building - Explosion-resistant security glazing – Test and classification by shock-tube loading
GSO ISO 16934:2009 Files
English
21 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable.
You can acquire it directly from its source or from one of the member countries stores
GSO ISO 16934:2009 Scope
This International Standard specifies a shock tube test method and classification requirements for explosionpressure-
resistant glazing, including glazing fabricated from glass, plastic, glass-clad plastics, laminated glass,
glass/plastic glazing materials, and film-backed glass. This International Standard provides a structured
procedure to determine the blast resistance and the hazard rating of glazing and glazing systems. This
International Standard sets out procedures to classify such security glazing sheet materials by means of tests
on specimens of a standard size in a standard frame for the purpose of comparing their relative explosion
resistance and hazard rating.
The procedures and test method can also be used to test, but not classify, glazing systems where the sheet
infill is incorporated into frames purposely designed as complete products of appropriate size for installation
into buildings. This International Standard applies a method of test and classifications against blast waves
generated in a shock tube facility to simulate high-explosive detonations of approximately 30 kg to 2 500 kg of
trinitrotoluene (TNT) at distances from about 35 m to 50 m. The classifications approximately represent the
reflected pressures and impulses that are experienced by these equivalent threat levels on the face of a large
building facade positioned perpendicular to the path of the blast waves.
Classification is defined in terms of both blast shock-wave characteristics, expressed in terms of peak
reflected pressure, impulse, positive phase duration and wave-form parameter (decay coefficient), and rating
criteria, expressed in terms of degrees of glazing damage and fragment impact hazard. Classifications and
ratings are assigned based upon the performance of the glazing and are specific to the blast characteristics
under which the test has taken place. Glazing that has received an air-blast classification and rating is suitable
for use in blast-resistant applications only for blasts of comparable characteristics and only if installed in a
properly designed frame. Design based on knowledge of the air-blast resistance reduces the risk of personal
injury.
Best Sellers From Construction and Building Sector
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 2489:2015
Gulf Standard
Specifications of Recycled Aggregates from Construction
Waste to be used in construction Works
GSO 2084:2010
Gulf Standard
Design and application of speed control humps
Recently Published from Construction and Building Sector
GSO ASTM C1170/C1170M:2026
ASTM C1170/C1170M:20
Gulf Standard
Standard Test Method for Determining Consistency and Density of Roller-Compacted Concrete Using a Vibrating Table
GSO ISO 679:2026
ISO 679:2009
Gulf Standard
Cement — Test methods — Determination of strength
GSO ISO 50002-2:2026
ISO 50002-2:2025
Gulf Standard
Energy audits — Part 2: Guidance for conducting an energy audit using ISO 50002-1 in buildings
GSO EN 14351-1:2006+A2:2026
EN 14351-1:2006+A2:2016
Gulf Standard
Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets