Fibre optic communication system design guides - Part 1: Single-mode digital and analogue systems
GSO IEC TR 61282-1:2014 Files
English
63 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable.
You can acquire it directly from its source or from one of the member countries stores
GSO IEC TR 61282-1:2014 Scope
This technical report provides system design methodology guidance to users and suppliers of fibre optic transmission systems for telecommunications and broadband video distribution applications. The function of the fibre optic systems considered in this technical report is to interconnect signals between defined digital and analogue interfaces via a fibre optic link. In general, fibre optic systems are built-up from basic fibre optic systems (BFOS). As a result, it is necessary to consider only the BFOS, which transmits a single electrical signal between two points without intermediate regeneration. Thus, these guidelines are applicable to almost all design cases.
As an initial step, only laser systems using direct detecting technologies in the 1 310 and/or 1 550 nm regions over B1 and B2 types of unshifted and dispersion shifted single-mode fibres are considered. For systems using longitudinal multi-mode lasers above approximately 0,5 Gb/s, the calculated dispersion limited lengths may be conservatively low. Bidirectional systems, in which both directions of transmission use a common fibre, and unidirectional systems are covered in this technical report.
In the clauses which follow, the transmission design parameters are specified by their worstcase values. It is the option of the user to require that suppliers guarantee the worst-case values over the lifetime of their respective system components. Some users or system designers may desire to perform analysis and design calculations via a statistical approach and to request statistical values of the parameters. The statistical approach is covered in annex A. The determination of the worst-case dispersion coefficient is covered in annex B.
Some examples are presented to clarify concepts and to illustrate order of magnitude. The numbers presented in these examples are illustrative only and should not be considered as requirements for system design or performance.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
GSO 1899:2016
Gulf Standard
GCC Standard voltages and frequencies for AC transmission and distribution systems
Recently Published from Electrical Sector
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines
GSO CEN/TR 16999:2026
CEN/TR 16999:2019
Gulf Standard
Solar energy systems for roofs - Requirements for structural connections to solar panels
GSO IEC 60884-2-7:2026
IEC 60884-2-7:2025
Gulf Standard
Plugs and socket-outlets for household and similar purposes - Part 2-7: Particular requirements for cord extension sets
GSO IEC TR 63411:2026
IEC TR 63411:2025
Gulf Standard
Grid connection of offshore wind via VSC-HVDC systems